Table of Contents
Can You Drink Tap Water in Wilkinsburg?
Yes, Wilkinsburg's tap water is generally considered safe to drink as Wilkinsburg has no active health based violations of the Safe Drinking Water Act (SDWA) that we are aware of. Other factors such as lead piping in a home, or low levels of pollutants on immunocompromised individuals, should also be considered, however. To find more recent info we might have, you can check out our boil water notice page or the city's water provider website.
According the EPA’s ECHO database, from April 30, 2019 to June 30, 2022, Wilkinsburg's water utility, Wilkinsburg-Penn Jt Water Auth, had 0 violations of the Safe Drinking Water Act. For more details on the violations, please see our violation history section below. The last violation for Wilkinsburg was resolved on June 30, 2018. This assessment is based on the Wilkinsburg-Penn Jt Water Auth water system, other water systems in the city may have different results.
While tap water that meets the EPA health guidelines generally won’t make you sick to your stomach, it can still contain regulated and unregulated contaminants present in trace amounts that could potentially cause health issues over the long-run. These trace contaminants may also impact immunocompromised and vulnerable individuals.
The EPA is reviewing if it’s current regulations around pollutant levels in tap water are strict enough, and the health dangers posed by unregulated pollutants, like PFAS.
Water Quality Report for Wilkinsburg Tap Water
The most recent publicly available numbers for measured contaminant levels in Wilkinsburg tap water are in its 2020 Water Quality Report. As you can see, there are levels which the EPA considers to be acceptable, but being below the maximum allowable level doesn’t necessarily mean the water is healthy.
Lead in tap water, for example, is currently allowed at up to 15ppb by the EPA, but it has set the ideal goal for lead at zero. This highlights how meeting EPA standards doesn’t necessarily mean local tap water is healthy.
EPA regulations continue to change as it evaluates the long term impacts of chemicals and updates drinking water acceptable levels. The rules around arsenic, as well as, lead and copper are currently being re-evaluated.
There are also a number of "emerging" contaminants that are not currently. For example, PFAS (Per- and polyfluoroalkyl substances), for which the EPA has issued a health advisory. PFAS are called "forever chemicals" since they tend not to break down in the environment or the human body and can accumulate over time.
We recommend looking at the contaminants present in Wilkinsburg's water quality reports, or getting your home's tap water tested to see if you should be filtering your water.
Wilkinsburg Tap Water Safe Drinking Water Act Violation History - Prior 10 Years
Below is a ten year history of violations for the water system named Wilkinsburg-Penn Jt Water Auth for Wilkinsburg in Pennsylvania. For more details please see the "What do these Violations Mean?" section below.
From April 1, 2018 to June 30, 2018, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring and Reporting (DBP) which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 2 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: Total Haloacetic Acids (HAA5).
From Jan. 1, 2016 to Dec. 31, 2016, Wilkinsburg had 5 non-health based Safe Drinking Water Act violations with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring, Regular which falls into the Chemicals rule code group, and the Inorganic Chemicals rule code family for the following contaminant codes: Cadmium, Nickel, Beryllium, Total, Chromium, Barium.
From Jan. 1, 2016 to Dec. 31, 2016, Wilkinsburg had 20 non-health based Safe Drinking Water Act violations with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring, Regular which falls into the Chemicals rule code group, and the Volatile Organic Chemicals rule code family for the following contaminant codes: 1,2,4-Trichlorobenzene, cis-1,2-Dichloroethylene, Xylenes, Total, DICHLOROMETHANE, o-Dichlorobenzene, p-Dichlorobenzene, 1,1-Dichloroethylene, trans-1,2-Dichloroethylene, 1,2-Dichloroethane, 1,1,1-Trichloroethane, Carbon tetrachloride, 1,2-Dichloropropane, 1,1,2-Trichloroethane, Tetrachloroethylene, Toluene, Styrene, Trichloroethylene, CHLOROBENZENE, Benzene, Ethylbenzene.
From Oct. 1, 2015 to Dec. 31, 2015, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring, Regular which falls into the Chemicals rule code group, and the Synthetic Organic Chemicals rule code family for the following contaminant code: Di(2-ethylhexyl) phthalate.
From May 1, 2015 to May 31, 2015, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring, Repeat Minor (TCR) which falls into the Microbials rule code group, and the Total Coliform Rules rule code family for the following contaminant code: Coliform (TCR).
From April 1, 2015 to June 30, 2015, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring and Reporting (DBP) which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From Jan. 1, 2015 to March 31, 2015, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring and Reporting (DBP) which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From Oct. 1, 2014 to Dec. 31, 2014, Wilkinsburg had 1 health-based Safe Drinking Water Act violation with the violation category being Treatment Technique Violation, more specifically, the violation code was Treatment Technique Precursor Removal which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From July 1, 2014 to Sept. 30, 2014, Wilkinsburg had 1 health-based Safe Drinking Water Act violation with the violation category being Treatment Technique Violation, more specifically, the violation code was Treatment Technique Precursor Removal which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From April 1, 2014 to June 30, 2014, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring and Reporting (DBP) which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From April 1, 2014 to June 30, 2014, Wilkinsburg had 1 health-based Safe Drinking Water Act violation with the violation category being Treatment Technique Violation, more specifically, the violation code was Treatment Technique Precursor Removal which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From Jan. 1, 2014 to March 31, 2014, Wilkinsburg had 2 non-health based Safe Drinking Water Act violations with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring and Reporting (DBP) which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 2 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant codes: Total Haloacetic Acids (HAA5), TTHM.
From Jan. 1, 2014 to March 31, 2014, Wilkinsburg had 1 health-based Safe Drinking Water Act violation with the violation category being Treatment Technique Violation, more specifically, the violation code was Treatment Technique Precursor Removal which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: CARBON, TOTAL.
From Jan. 1, 2014 to Dec. 31, 2014, Wilkinsburg had 17 non-health based Safe Drinking Water Act violations with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring, Regular which falls into the Chemicals rule code group, and the Synthetic Organic Chemicals rule code family for the following contaminant codes: Endrin, Toxaphene, Dalapon, Diquat, Endothall, Glyphosate, Picloram, Dinoseb, Carbofuran, 2,4-D, 2,4,5-TP, Pentachlorophenol, Total Polychlorinated Biphenyls (PCB), OXAMYL, Chlordane, ETHYLENE DIBROMIDE, 1,2-DIBROMO-3-CHLOROPROPANE.
For the compliance period beginning Dec. 12, 2013, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Other Violation, more specifically, the violation code was Public Notification Violation for NPDWR Violation which falls into the Other rule code group, and the Public Notice Rule rule code family for the following contaminant code: Public Notice.
From Nov. 1, 2013 to Nov. 30, 2013, Wilkinsburg had 1 health-based Safe Drinking Water Act violation with the violation category being Treatment Technique Violation, more specifically, the violation code was Treatment Technique (SWTR and GWR) which falls into the Microbials rule code group, and the Surface Water Treatment Rules rule code family for the following contaminant code: Surface Water Treatment Rule.
From Oct. 1, 2011 to Dec. 31, 2011, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring and Reporting (DBP) which falls into the Disinfectants and Disinfection Byproducts Rule rule code group, and the Stage 1 Disinfectants and Disinfection Byproducts Rule rule code family for the following contaminant code: Total Haloacetic Acids (HAA5).
From Oct. 1, 2011 to Dec. 31, 2011, Wilkinsburg had 1 non-health based Safe Drinking Water Act violation with the violation category being Monitoring and Reporting, more specifically, the violation code was Monitoring, Regular which falls into the Chemicals rule code group, and the Synthetic Organic Chemicals rule code family for the following contaminant code: Total Polychlorinated Biphenyls (PCB).
Is there Lead in Wilkinsburg Water?
Based on the EPA’s ECHO Database, 90% of the samples taken from the Wilkinsburg water system, Wilkinsburg-Penn Jt Water Auth, between sample start date and sample end date, were at or below, 0.01286 mg/L of lead in Wilkinsburg water. This is 85.7% of the 0.015 mg/L action level. This means 10% of the samples taken from Wilkinsburg contained more lead.
While Wilkinsburg water testing may have found 0.01286 mg/L of lead in its water, that does not mean your water source has the same amount. The amount of lead in water in a city can vary greatly from neighborhood to neighborhood, or even building to building. Many buildings, particularly older ones, have lead pipes or service lines which can be a source of contamination. To find out if your home has lead, we recommend getting you water tested.
No amount of lead in water is healthy, only less dangerous. As lead accumulates in our bodies over time, even exposure to relatively small amounts can have negative health effects. For more information, please check out our Lead FAQ page.
Are there PFAS in Wilkinsburg Tap Water?
Currently, testing tap water for PFAS isn’t mandated on a national level. We do have a list of military bases where there have been suspected or confirmed leaks. There appears to be at least one military base - ANG Pittsburgh - near Wilkinsburg with suspected leaks.
With many potential sources of PFAS in tap water across the US, the best information we currently have about which cities have PFAS in their water is this ewg map, which you can check to see if Wilkinsburg has been evaluated for yet.
Our stance is better safe than sorry, and that it makes sense to try to purify the tap water just in case.
Wilkinsburg SDWA Violation History Table - Prior 10 Years
Compliance Period | Status | Health-Based? | Category Code | Code | Rule Code | Contaminant Code | Rule Group Code | Rule Family Code |
---|---|---|---|---|---|---|---|---|
04/01/2018 - 06/30/2018 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 2 Disinfectants and Disinfection Byproducts Rule (220) | Total Haloacetic Acids (HAA5) (2456) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 2 Disinfectants and Disinfection Byproducts Rule (220) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Inorganic Chemicals (333) | Cadmium (1015) | Chemicals (300) | Inorganic Chemicals (330) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Inorganic Chemicals (333) | Nickel (1036) | Chemicals (300) | Inorganic Chemicals (330) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Inorganic Chemicals (333) | Beryllium, Total (1075) | Chemicals (300) | Inorganic Chemicals (330) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | 1,2,4-Trichlorobenzene (2378) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | cis-1,2-Dichloroethylene (2380) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Xylenes, Total (2955) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | DICHLOROMETHANE (2964) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | o-Dichlorobenzene (2968) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | p-Dichlorobenzene (2969) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | 1,1-Dichloroethylene (2977) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | trans-1,2-Dichloroethylene (2979) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | 1,2-Dichloroethane (2980) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | 1,1,1-Trichloroethane (2981) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Carbon tetrachloride (2982) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | 1,2-Dichloropropane (2983) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | 1,1,2-Trichloroethane (2985) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Tetrachloroethylene (2987) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Toluene (2991) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Styrene (2996) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Inorganic Chemicals (333) | Chromium (1020) | Chemicals (300) | Inorganic Chemicals (330) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Inorganic Chemicals (333) | Barium (1010) | Chemicals (300) | Inorganic Chemicals (330) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Trichloroethylene (2984) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | CHLOROBENZENE (2989) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Benzene (2990) | Chemicals (300) | Volatile Organic Chemicals (310) |
01/01/2016 - 12/31/2016 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Volatile Organic Chemicals (310) | Ethylbenzene (2992) | Chemicals (300) | Volatile Organic Chemicals (310) |
10/01/2015 - 12/31/2015 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Di(2-ethylhexyl) phthalate (2039) | Chemicals (300) | Synthetic Organic Chemicals (320) |
05/01/2015 - 05/31/2015 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Repeat Minor (TCR) (26) | Total Coliform Rule (110) | Coliform (TCR) (3100) | Microbials (100) | Total Coliform Rules (110) |
04/01/2015 - 06/30/2015 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
01/01/2015 - 03/31/2015 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
10/01/2014 - 12/31/2014 | Resolved | Yes | Treatment Technique Violation (TT) | Treatment Technique Precursor Removal (46) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
07/01/2014 - 09/30/2014 | Resolved | Yes | Treatment Technique Violation (TT) | Treatment Technique Precursor Removal (46) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
04/01/2014 - 06/30/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
04/01/2014 - 06/30/2014 | Resolved | Yes | Treatment Technique Violation (TT) | Treatment Technique Precursor Removal (46) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
01/01/2014 - 03/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 2 Disinfectants and Disinfection Byproducts Rule (220) | Total Haloacetic Acids (HAA5) (2456) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 2 Disinfectants and Disinfection Byproducts Rule (220) |
01/01/2014 - 03/31/2014 | Resolved | Yes | Treatment Technique Violation (TT) | Treatment Technique Precursor Removal (46) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | CARBON, TOTAL (2920) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Endrin (2005) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Toxaphene (2020) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Dalapon (2031) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Diquat (2032) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Endothall (2033) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Glyphosate (2034) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Picloram (2040) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Dinoseb (2041) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Carbofuran (2046) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | 2,4-D (2105) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | 2,4,5-TP (2110) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Pentachlorophenol (2326) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Total Polychlorinated Biphenyls (PCB) (2383) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | OXAMYL (2036) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Chlordane (2959) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | ETHYLENE DIBROMIDE (2946) | Chemicals (300) | Synthetic Organic Chemicals (320) |
01/01/2014 - 03/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 2 Disinfectants and Disinfection Byproducts Rule (220) | TTHM (2950) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 2 Disinfectants and Disinfection Byproducts Rule (220) |
01/01/2014 - 12/31/2014 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | 1,2-DIBROMO-3-CHLOROPROPANE (2931) | Chemicals (300) | Synthetic Organic Chemicals (320) |
12/12/2013 - | Resolved | No | Other Violation (Other) | Public Notification Violation for NPDWR Violation (75) | Public Notice Rule (410) | Public Notice (7500) | Other (400) | Public Notice Rule (410) |
11/01/2013 - 11/30/2013 | Resolved | Yes | Treatment Technique Violation (TT) | Treatment Technique (SWTR and GWR) (41) | Surface Water Treatment Rule (121) | Surface Water Treatment Rule (0200) | Microbials (100) | Surface Water Treatment Rules (120) |
10/01/2011 - 12/31/2011 | Resolved | No | Monitoring and Reporting (MR) | Monitoring and Reporting (DBP) (27) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) | Total Haloacetic Acids (HAA5) (2456) | Disinfectants and Disinfection Byproducts Rule (200) | Stage 1 Disinfectants and Disinfection Byproducts Rule (210) |
10/01/2011 - 12/31/2011 | Resolved | No | Monitoring and Reporting (MR) | Monitoring, Regular (03) | Synthetic Organic Chemicals (320) | Total Polychlorinated Biphenyls (PCB) (2383) | Chemicals (300) | Synthetic Organic Chemicals (320) |
What do these Violations Mean?
Safe Drinking Water Act Violations categories split into two groups, health based, and non-health based. Generally, health based violations are more serious, though non-health based violations can also be cause for concern.
Health Based Violations
- Maximum contaminant levels (MCLs) - maximum allowed contaminant level was exceeded.
- Maximum residual disinfectant levels (MRDLs) - maximum allowed disinfectant level was exceeded.
- Other violations (Other) - the exact required process to reduce the amounts of contaminants in drinking water was not followed.
Non-Health Based Violations
- Monitoring and reporting violations (MR, MON) - failure to conduct the required regular monitoring of drinking water quality, and/or to submit monitoring results on time.
- Public notice violations (Other) - failure to immediately alert consumers if there is a serious problem with their drinking water that may pose a risk to public health.
- Other violations (Other) - miscellaneous violations, such as failure to issue annual consumer confidence reports or maintain required records.
SDWA Table Key
Field | Description |
---|---|
Compliance Period | Dates of the compliance period. |
Status |
Current status of the violation.
|
Health-Based? | Whether the violation is health based. |
Category Code |
The category of violation that is reported.
|
Code | A full description of violation codes can be accessed in the SDWA_REF_CODE_VALUES (CSV) table. |
Contaminant Code | A code value that represents a contaminant for which a public water system has incurred a violation of a primary drinking water regulation. |
Rule Code |
Code for a National Drinking Water rule.
|
Rule Group Code |
Code that uniquely identifies a rule group.
|
Rule Family Code |
Code for rule family.
|
For more clarification please visit the EPA's data dictionary.
Wilkinsburg Water - Frequently Asked Questions
By Mail: | 2200 ROBINSON BLVD WILKINSBURG, PA, 15221 |
Existing customers can login to their Wilkinsburg-Penn Jt Water Auth account to pay their Wilkinsburg water bill by clicking here.
If you want to pay your Wilkinsburg-Penn Jt Water Auth bill online and haven't made an account yet, you can create an account online. Please click here to create your account to pay your Wilkinsburg water bill.
If you don't want to make an account, or can't remember your account, you can make a one-time payment towards your Wilkinsburg water bill without creating an account using a one time payment portal with your account number and credit or debit card. Click here to make a one time payment.
Moving to a new house or apartment in Wilkinsburg means you will often need to put the water in your name with Wilkinsburg-Penn Jt Water Auth. In order to put the water in your name, please click the link to the start service form below. Start service requests for water bills typically take two business days.
Leaving your house or apartment in Wilkinsburg means you will likely need to take your name off of the water bill with Wilkinsburg-Penn Jt Water Auth. In order to take your name off the water bill, please click the link to the stop service form below. Stop service for water bills requests typically take two business days.
USER SUBMITTED RATINGS
- Drinking Water Pollution and Inaccessibility
- Water Pollution
- Drinking Water Quality and Accessibility
- Water Quality
The above data is comprised of subjective, user submitted opinions about the water quality and pollution in Wilkinsburg, measured on a scale from 0% (lowest) to 100% (highest).
Related FAQS
Wilkinsburg Water Quality Report (Consumer Confidence Report)
The EPA mandates that towns and cities consistently monitor and test their tap water. They must report their findings in an annual Consumer Confidence Report. Below is the most recent water quality report from Wilkinsburg's Water. If you would like to see the original version of the report, please click here.
Contaminants
Wilkinsburg-penn Joint Water Authority
EWG's drinking water quality report shows results of tests conducted by the water utility and provided to the Environmental Working Group by the Pennsylvania Department of Environmental Protection, as well as information from the U.S. EPA Enforcement and Compliance History database (ECHO). For the latest quarter assessed by the U.S. EPA (January 2019 - March 2019), tap water provided by this water utility was in compliance with federal health-based drinking water standards.
Utility details
- Serves: 120000
- Data available: 2012-2017
- Data Source: Surface water
- Total: 14
Contaminants That Exceed Guidelines
- Bromodichloromethane
- Bromoform
- Chloroform
- Chromium (hexavalent)
- Dibromochloromethane
- Nitrate
- Total trihalomethanes (TTHMs)
Other Detected Contaminants
- Chromium (total)
- Fluoride
- Haloacetic acids (HAA5)
- Mercury (inorganic)
- Molybdenum
- Nitrite
- Strontium
Reminder
Always take extra precautions, the water may be safe to drink when it leaves the sewage treatment plant but it may pick up pollutants during its way to your tap. We advise that you ask locals or hotel staff about the water quality. Also, note that different cities have different water mineral contents.